How to set multi times weigh of multihead weigher

First, open recipe(for example, if use 10 head weigher weigh 4000g, weighingtwice, open recipe of weighing 2000g) Open the first page of parameter setting interface, change target weight to4000g. Find parameter of “Multi Combine Times” in the second page of parametersetting interface, change to 2. Click the button in the parameter setting interface, then enter the function [...]

By |2024-05-19T03:22:27+00:00May 6th, 2024|Troubleshooting|Comments Off on How to set multi times weigh of multihead weigher

Frequency converter setting

1.Check weigher frequency converter setting 2-00:d1, frequency enter source, by external current 0-10v 2-01:d2, operated by external terminal. Keyboard STOP can work. 4-04:d2,M0: run/stop, M1: forward/reverse 1-00:60 1-01:60 2-00:d1, frequency enter source, by external current 0-10v 2-01:d2, operated by external terminal. Keyboard STOP can work. 4-04:d2,M0: run/stop, M1: forward/reverse 1-00:60 1-01:60   1-09 the first acceleration time [...]

By |2024-05-12T04:00:43+00:00May 5th, 2024|Troubleshooting|Comments Off on Frequency converter setting

How to plug correctly after replacing the circuit board

1.Open the cabinet which is on the face of switch as below picture, and find out power supply. 2.Then measure 203+ and 203- by multimeter, valid voltage should be DC24V . 3.If the voltage is 24V, which means the power supply is no problem, the problem will be either screen or the cable which connect between cabinet [...]

By |2024-05-12T04:40:47+00:00May 4th, 2024|Troubleshooting|Comments Off on How to plug correctly after replacing the circuit board

How to solve failure of touch screen-12 head linear weigher

1.Open the cabinet which is on the face of switch as below picture, and find out power supply. 2.Then measure 203+ and 203- by multimeter, valid voltage should be DC24V . 3.If the voltage is 24V, which means the power supply is no problem, the problem will be either screen or the cable which connect between cabinet [...]

By |2024-05-12T04:51:16+00:00May 2nd, 2024|Troubleshooting|Comments Off on How to solve failure of touch screen-12 head linear weigher

The fault processing method for all hoppers open door twice

Firstly, take down the No.1 aluminum box, find motor position line and measurethe voltage to see whether there is about 18 v DC by a multimeter. If there is no 18 v voltage, open the machine frame that is on the right of the emergentstop button Find out the main board of multihead weigher, there is [...]

By |2024-05-12T04:57:49+00:00May 1st, 2024|Troubleshooting|Comments Off on The fault processing method for all hoppers open door twice

How to adjust material thickness in a reasonable way

Analysis: The thickness of the material directly affects the multihead weigher’s accuracy, thus affecting the actual production accuracy. If the material is too thick ,the phenomenon of excess weight is often present. If too thin,weighing hopper feed for many times so as to affect the rate of combined balance, the weigher’s speed will be slower as [...]

By |2024-05-13T04:21:25+00:00April 30th, 2024|Troubleshooting|Comments Off on How to adjust material thickness in a reasonable way