Frequency converter setting

1.Check weigher frequency converter setting

2-00:d1, frequency enter source, by external current 0-10v

2-01:d2, operated by external terminal. Keyboard STOP can work.

4-04:d2,M0: run/stop, M1: forward/reverse

1-00:60

1-01:60

2-00:d1, frequency enter source, by external current 0-10v

2-01:d2, operated by external terminal. Keyboard STOP can work.

4-04:d2,M0: run/stop, M1: forward/reverse

1-00:60

1-01:60

 

1-09 the first acceleration time 2

1-10 the first deceleration time 2

1-11 the second acceleration time 2

1-12 the second deceleration time 2

 

2 .Rotary top cone frequency converter setting

2-00:d1, frequency enter source, by external 0-10v

2-01:d2, operated by external terminal, keyboard STOP can’t work.

4-04:d2,M0: run/stop,M1: forward/reverse

1-00:80

1-01:80

 

1-09 the first acceleration time 2

1-10 the first deceleration time 2

1-11 the second acceleration time 2

1-12 the second deceleration time 2

 

3.Linear combination weigher main belt frequency converter setting

2-00:d1, frequency enter source, by external current 0-10v

2-01:d1,operated by external terminal. Keyboard STOP can work.

4-04:d2,M0: run/stop, M1: forward/reverse

1-00:80

1-01:80

1-09:0.5

1-10:0.5

1-11:0.5

1-12:0.5

 

4.Linear combination weigher small belt frequency converter setting

enter password:123

F-03  1

F-06   3

F-07   1400

F-09   0.2

F-13   0.2